Local transformer on fire how much should I worry?
Local transformer on fire how much should I worry?
911 and the local electrical company have been contacted. A storm came through, we lost power, it came back but fluctuates. We then noticed that the local transformer was on fire. I was alarmed at the sound and concept but my husband wasn’t that phased. How common is this and how much should I worry? We are not in a fire prone area.
Is my ground in the wrong spot??
Is my ground in the wrong spot??
The white ground is going out to the pole and the green one is my grounding rod, should the green one not be bonded to the pannel not the bus bar?
Note not an electrician, but my copper water lines feel live and a few switches in my house give us shocks
How do I turn off power to the whole house?
How do I turn off power to the whole house?
I need to replace a faulty breaker. Here's a picture of my main breaker box. There's no master switch that I can see that shuts off power to all of the breakers.
Following the line up and out of the box, it runs along the basement ceiling and out through a hole in the foundation.
Let me know if you need to see something else.
Edit. Resolved! I found a master switch on the outside of the house in a panel adjacent to the meter. Weird that anyone can just walk up to my house and turn all of the power off.
(MN:USA) Becoming liscensed without an apprenticeship?
(MN:USA) Becoming liscensed without an apprenticeship?
So I'm a refrigeration mechanic and I want to continue being a refrigeration mechanic. I love my job and I have no interest in becomming a full time electrician. However having the certs to do some light electrical work would be very helpful in my job because my state is very strict about what you can and can't do without being a licensed electrician. It is tremendously annoying that I can rewire an entire rooftop airhandler running 480V 3phase and drawing 100A without breaking any laws but I would be breaking the law if I replaced a faulty breaker in a pannel or fixed a miswired disconnect switch. I can't even run thermostat wire here without a low voltage cert. But as far as I can tell the only way to get those certs would be to quit my job which I love and apprentice for several years under an electrician. I don't want to wire up entire electrical panels or setup industrial motor drive cabinets, but being able to ocasionally replace a bad GFCI outlet or a crappy disconnect would be nice.
Is there any way to become licensed to do even light electrical work without having to quit my current job?
Question About Power Supply Rating vs. Multimeter Reading (Solved)
Question About Power Supply Rating vs. Multimeter Reading (Solved)
Back story: For the past year I have a set of LEDs in my kitchen, and recently they started turning off, changing brightness, switching to different modes all by themselves. I thought maybe the controller went bad and was failing, so I replaced it a couple of weeks ago. Yesterday they started exhibiting similar behaviors again. So I’m wondering now if the power supply is failing and it’s causing the controller to do weird things. I grabbed my multimeter to see what kind of voltage the power supply is putting out, and it’s giving me 52V. The power supply is supposed to give 24V output (see screenshot below), so I’m confused and was hoping someone could help me understand why I’m getting over 2x the voltage? I do apologize if this is not the right place. I saw an askelectronics community, but their rules say no electrical, and at this juncture I believe my question is electrical. If there is a better place for this kind of question, I would appreciate a pointer to the better place. image Edit: I am a dummy. Less so as of right now, but yeah, it was user error. So I learned today that the multimeter can read both DC and AC voltages, and my power supply is 24V in DC, while I was reading it in AC. 🤦♂️ Once I switched to using DC, the power supply read 24V (in multiple outlets).
Tracking down some faults and found this buried under the drywall.
Tracking down some faults and found this buried under the drywall.
How can I bring this forward so the junction box is accessible?
Do I just get enough single gang extension rings to bring it out far enough to sit flush with the drywall?
Or do I add an access panel on the drywall?
Guy im helping with a panel swap is no fun at all
Guy im helping with a panel swap is no fun at all
Typo in the screenshot godDAMMIT He and I worked together at a supply house. Im not sure i can shoplift one from the others. Damn. How do i tell him it doesn't have to be his? image
How to wire bathroom fan timer
How to wire bathroom fan timer
Hi all. I have a bathroom fan on a simple switch but wanted to upgrade it to a time. When I pulled the switch out of the wall I found one ground wire, and a singe wire with some of the sheathing removed to loop around the other terminal. Can I cut the looped wire and connect it to the load / line on the timer? Then I connect the ground to the uncapped ground/neutral on the switch? image image Edit: the advice worked. I put the unlooped black wire with one of the black wires on the timer. I cut the black loop and tied the two wires to another black wire on the timer. I put another grounding wire on the metal box and attached it to ground. Likewise, I pigtailed the neutral bundle and connected to neutral. It took a few tries to get the box to close correctly since the timer is so big, but it worked out! Thanks again all.
More weird potential offsets
More weird potential offsets
Some of you may recall my previous post about a ~20V potential between my electrical ground and my concrete slab. That's still not resolved - it's currently sitting just under 10V.
Today I have a new mystery - to me anyway..
I'm sitting at my desk and notice that I got a tingle from the outer shield/shell of a USB-C cable. I got my multi-meter and measured 65V from the cable to me with my bare feet on the slab! It drops to about 16V if I lift my feet off the floor. I immediately assumed the charging brick it's plugged into was faulty, but just in case I took a more measurements and found that the another similar charger has a similar offset, the "ground" part of a TRS cable plugged into an amplifier is similar, the accessible metal shield part of a USB-A port on an ASUS ChromeBox is similar. I assume that's not normal?
This is a new slab on grade build. Ground and neutral are properly bonded - I checked a few outlets and ground to neutral is ~0.3V.
Edit - I don't think there is any safety risk - I measured 0.3μA current.
Follow up to my question about outdoor lamps
Follow up to my question about outdoor lamps
Please check out my previous post here. I'd like to say thank you to everyone who helped me with my last question. Hopefully you can help me again... I had a look at my setup, and the system actually has 70 lamps. That implies that each one likely draws 0.1W (if I understand this correctly) given that the transformer has a Max output of 9W. I'm having a hard time finding lamps that fit this spec, so now I'm wondering if I could simply change the transformer. Do I risk melting the wires or burning my house down doing something like this?
Post mortem - What was the cause?
Post mortem - What was the cause?
I want to know what do you think? What was probable cause? Before that, for last 2-ish years I must replaced 5 LED bulbs. No other symptoms. Right before failure, one or two LED bulbs started blinking. I heard "scorching" sound. And smell of burned electric/electronic (isolation). Then I disconnected all circuits and opened all surrounding boxes... Over-current breakers or RCD/GFCI didn't tripped. Extra photos: (ignore temporary jumper - fixed now) image image image image
Wiring Check: Is the wiring correct?
Wiring Check: Is the wiring correct?
I'm trying to wire Shelly 1PM gen 3 to my wall outlet. Is the diagram correct?
That ain't gonna file down
That ain't gonna file down
Bonus: image Service call for a smoking main 200a breaker. Ended up shifting the entire bussing up to get fresh bus clips, covered the top of the bussing protruding beyond the backing with a comical amount of mastic, installed a new main breaker, and told the client they need to change that service yesterday. Old 80s/90s Crouse-Hinds, those mains are garbage.
Help! I dont understand my lighting, and need help figuring out which lamps I need
Help! I dont understand my lighting, and need help figuring out which lamps I need
A couple years ago, I bought a string of led festoon lamps. This was a cheap purchase from a Chinese seller on Amazon, who is no longer actively trading. The strings came with a couple spare lamps, but now they have all been used up and I need to find some new ones. The issue is that the packaging has no indication of their spec, and the lamps themselves have no markings on them, so this is quite tricky. I tried getting these. They fit in the socket, so thats a good start, but they don't light up. Before I go out searching for something again, can someone help me figure out if it's a lost cause and I should just buy a new string or if it is possible to work out what type of lamp I require. The picture is of the plug/transformer. It's the only info I have to go off...
UK: electrician vs cable jointer vs meter installer
UK: electrician vs cable jointer vs meter installer
What's the least expensive way to enter these careers?
Which career would you rather have, and why?
Extractor fan replacement
Extractor fan replacement
Hi all. Looking for advice, my fan died so I bought a replacement to find it's not the same model. It's too late for an eBay return now.
I have pretty much zero electrics knowledge beyond wiring a plug 15 years ago. I work in IT so "open it, move each wire one to one, one by one" didn't seem too challenging. But I have a two wire fan to replace a three wired one. I believe I lose the timer function?
So should I just buy the right one and go with Plan A? It's a small bathroom only about three times the size of the shower cubicle. I remember being told I would need more throughput than the cheap thing in place when I moved in. This one would only stay on as long as the light is on, is that right, so not expelling moisture for a while after use?
Should I still use this one but get it installed by a professional if it's not like for like? I've identified the breaker for the lights, have bought a voltage tester screwdriver thingy, will stand on a wooden stool and hold my belt behind my back with my left hand. That's all the safety awareness I have.
Thanks in advance. UK based if it makes a difference. "Image uploads appear to be down" in my lemmy app so apologies, will try to add photos later.
Random weekend photo: switch replacement
Random weekend photo: switch replacement
Put in a matter-enabled switch here for house exterior lights. This was the only photo I took -- the wires prior to starting work ;)
20V AC between slab and electrical ground
20V AC between slab and electrical ground
I've just had a new house built in Atlantic Canada. This morning I noticed a bit of a tingle from my coffee machine when I touched it with wet hands. The machine has a grounded (3 pin) plug and I checked - it has 0V between the parts I touched (the entire metal outer case) and the ground socket in the outlet. So, I got curious and did some more measurements. It turns out there is 20V AC (and about 300mV DC) between the ground in my outlets and me when I'm standing on my floor (sealed concrete slab) with bare feet.
I assume this isn't good?
I'll be calling the electrician that wired the house in the morning, but I'd appreciate any insights you might have.
208V or 240V Three Phase for Residential Home? Any big pitfalls other than price?
208V or 240V Three Phase for Residential Home? Any big pitfalls other than price?
Location: USA:MN To preface, I'm a refrigeration mechanic, so I only know just enough about three phase power to get into trouble hook things up and make sure they work. I'm working on a large remodeling project in my home durring which I want to future proof as much as I can (because foam insulation makes changing things later a bitch). I'm going the full 9 yards running conduit and everything. As part of that future proofing I am planning on upgrading my service from 100A to 200A. However, since I'm upgrading my service anyways, I am also strongly considering getting a three phase service. If I ever wanted to stick an electric car charger or other big piece of equipment in then a three phase connection would be handy to have. It also seems like the kind of upgrade I want to get done while the house is mostly gutted rather than trying to shoehorn it in later. So my questions are as follows. 1. Do I go with a 120/208V 4 wire service or a 120/240V 4 wire service? My provider offers both to residential customers in my area. There are additional restriction on the service drop for the 240V option. None of those appear to apply in my case but it might make 240V a bit more of a pain to get. • 2. Do I need to worry about phase balance? Since this is for a single family home most of my power draw is going to still be 120V between a single phase and neutral. Obviously I want to split circuits up between the 3 phases to try to draw on them evenly, but it's never going to be split perfectly evenly. Is drawing on the phases unevenly going to cause any sort of issue? • 3. Are there any other footguns to watch out for here? For example, is having three phase power going to mess with my home insurance rates or anything like that?
Supply voltage variance
Supply voltage variance
I live in a small community at the end of a long line in Atlantic Canada. We get frequent power disruptions so I have installed a backup generator. I have a bit of a home lab, and don't like my server to lose power with no warning so I've recently installed a small UPS to keep it running in the gap between my power going out and the generator starting. The UPS logs data and lets me access it.
I'm wondering if I should be concerned about my input voltage. The blue line in the minimum for the hour, the amber is maximum for the hour. The zero period on the 8th of March was when I had the power turned off to do some work.
The default configuration for my UPS has it cut over to battery power at 88V, so it seems some significant variation is expected!
I tried searching my power company web site but they don't seem to publish anything about guaranteed, or even expected, supply voltage.